© 2007 Schneider Electric. All Rights Reserved.63230-216-229-B1
Use
SFT2841 Set Up and Operating
Software
General Screen Organization
Use
Screen Details
Password identification: entry gives access rights
to the parameter and protection setting mode
(valid for 5 minutes).
Selecting a new application from a list with
factory settings. The file suffix identifies the
application. For example, "appli.G87" is for a
Generator 87 application
Opening an existing application located in the
SFT2841 directory, Sepam™ sub-directory. An
application may be selected by choosing the type
of file (for example,: file type *.S80, or *. G87 or
*.* to obtain the complete list of files)
To save an application, go to SFT2841 directory,
Sepam™ sub-directory, and name the file. The
application suffix automatically updates.
Configuring and complete or partial printing of
the current configuration file
Print preview of the configuration file
Hard-copy of the current screen
Sepam™ parameter setting:
v "Sepam™ hardware" tab: configuration.
v "General characteristics" tab: setting network,
remote control,monitoring, password
management and Sepam™ label printing
parameter.
v "CT/VT sensors" tab: configuring current and
voltage sensors
v "CT/VT supervision" tab: implementating and
configuring CT and VT sensor supervision
v "Particular characteristics" tab: transformer and
motor/generator rotation speed parameter
setting.
v "Control logic" tab: parameter setting logic
discrimination, switchgear control, genset
shutdown, de-excitation, load shedding, and
restart functions
v "Logic I/Os" tab: manage logic input and output
assignments
Protection functions:
v "Application" tab: overview of protection
functions available in the application with
graphical view of single-line diagram. Double
click on a protection function label to gain quick
access to the setting tab
v One tab per protection function: setting the
parameters of each protection function. Gives a
mini-matrix for setting outputs, LEDs, and
disturbance recording
Create logic equations: See description in
"Control and monitoring functions" chapter
Logipam: Program setup and operation. First
enter and confirm the program before using the
SFT2885 software.
Control matrix: used to assign logic outputs,
LEDs and messages to information produced by
the protection units, logic inputs and logic
equations. This function may also be used to
create messages. See "Creating User
Messages".
PE50153
Example of tripping contexts screen
Special functions:
v "Rec" tab: Disturbance-recording function parameter setting
v "Mimic-based UMI" tab: Mimic-based UMI parameter setting.
Sepam™ diagnosis
(1)
v "Diagnosis" tab: general characteristics, software version, fault indicator,
and Sepam™ time-setting
v "Input, output and LED status" tab: gives status and proposes an output test
v "Remote indication status" tab: remote indication status
Main measurements
(1)
v "VIF" tab: voltage, current and frequency values
v "Other" tab: power, energy and rotation speed values
v "Temperatures" tab
v "Phasor" diagram tab
Diagnosis
(1)
v Network tab: unbalance / negative sequence, V-I phase displacement,
number of phase and ground trips, and total harmonic distortion values
v Machine tab: running hours counter, differential and through current,
impedance, I-I’ phase displacement, H3 voltage, and thermal overload
values
v "Tripping context" tab: gives the last 5 tripping contexts
Switchgear diagnosis: cumulative breaking current, auxiliary voltage and
circuit breaker data
(1)
Management of alarms with history and time-tagging
(1)
Disturbance recording:
(1)
this function is used to record analog signals and
logical states. See "Disturbance recording".
Guided navigation (see previous page)
On-line help (see previous page)
(1) These icons are only accessible in "connected to Sepam™" mode.