Hardware Installation Guide
revision 1 — 171
9. At this point, make sure that switch 5 on the ISC is configured correctly for hardware flow control. It
should be set to “ON.”
10. To verify that the device is talking on the network you can “ping” from the command prompt by typing
ping IP address.
30.8.1 Wiring Configuration for Custom DB25 Serial Cable
The cable for the UDS must be a straight through cable. The Other LANTRONIX devices, such as the MSS-
100, require a null cable for serial communication to the ISC. The cable is also different because the MSS-
100 uses a serial cable with a female DB25 connector. The UDS custom cable must have a male connector
because the fixed serial port on the device has a female adapter.
Note: Refer to the manufacturer installation manual for more information on the custom cable and
pin out information.
30.8.2 Connecting the UDS with an ISC
These units operate on 10-base T. Make sure that if connected to a hub, that it is 10 base T or auto-sensing
10/100.
TXD Pin 2
RXD Pin 3
RTS Pin 4
CTS Pin 5
GND Pin 7